KangarooSci Microbiology Count Plates
Dry-film microbiological count plates for the food and beverage QC lab — AOAC-RI certified Aerobic Count Plate, plus Coliform, E. coli, Yeast & Mould, Staphylococcus aureus and more. Faster, simpler, more cost-efficient than traditional agar-pour-plate methods.
AOAC-RI certified
The KangarooSci Aerobic Count Plate is AOAC Research Institute Performance Tested — the independent validation of accuracy against the reference agar method.
Simpler workflow than agar
Peel film, apply 1 ml sample, press, incubate. No molten agar, no autoclaving, no plating-out. Reduces technician time + consumable cost.
Full dairy + food range
Aerobic Count, Coliform, E. coli, Yeast & Mould, Staph. aureus — the full set the dairy + food QC lab needs for routine microbial testing.
KangarooSci Count Plates in stock
KangarooSci Aerobic Count Plate (AOAC-RI certified)
Total aerobic plate count — the fundamental hygiene indicator. AOAC-RI certified against the agar-pour-plate reference method. 24-48 hour incubation; red-colony count.
KangarooSci Coliform Count Plate
Coliform count — the sanitary quality indicator for dairy, water and food matrices. 24 hour incubation.
KangarooSci E. coli Count Plate
E. coli specifically — essential for raw milk, water, and ready-to-eat food matrices. Differential chromogenic film.
KangarooSci Yeast & Mould Count Plate
Yeast + mould count — critical for shelf-life assessment of fermented products, beverages, and dairy. 3-5 day incubation.
KangarooSci Staphylococcus aureus Count Plate
Staph. aureus specifically — toxin-producing pathogen; essential for RTE food + dairy monitoring. 24 hour incubation.
KangarooSci ATP Kit (hygiene swab)
ATP luminescence hygiene monitoring — real-time surface cleanliness measurement for CIP (Cleaning-In-Place) verification. Complements the count-plate workflow.
Which count plate for which scenario
Dairy processor hygiene monitoring
Aerobic Count Plate on raw milk + CIP rinses + finished product. Coliform / E. coli for sanitation indicators. ATP hygiene swabs for surface cleanliness real-time.
Beverage / water testing
Aerobic + Coliform + E. coli for bottled water + beverage product QC. Yeast & Mould for shelf-life + fermentation monitoring.
RTE food QC
Full panel — Aerobic + Coliform + E. coli + Staph. aureus + Yeast & Mould. The standard dairy / ready-to-eat food shelf-life + safety-release workflow.
SANAS lab routine workflow
Count plates replace agar-pour-plate methods in SANAS-accredited labs — AOAC-RI certification supports the ISO/IEC 17025 validation. Faster workflow, less consumable waste.
Frequently asked questions
How do count plates compare to agar?
Count plates give equivalent results to the agar-pour-plate reference method (AOAC-RI certified for Aerobic Count). Workflow is 2-3x faster, no molten-agar handling, no autoclave required, less reagent waste. Standard adoption in modern QC labs.
Shelf life + storage?
Count plates typically have 12-18 month shelf life at 2-8 °C refrigeration. Full lot-specific expiry on each package.
What incubation do I need?
Standard microbiology incubator (we also stock the Mini Incubator / Heating Block if a benchtop option fits). Temperatures per plate type — Aerobic 30-35 °C 48h, Coliform 35 °C 24h, Yeast & Mould 25 °C 3-5 days.
How do I count the colonies?
Visual red / purple / blue colony count against the printed grid on the film. Smartphone-based colony-counter apps work too. Manual count typically 1-5 min per plate once experienced.
Can we use these for SANAS-accredited lab release?
Yes — the AOAC-RI certification supports ISO/IEC 17025 validation. Specific SANAS scope needs the lab's internal method validation + ongoing proficiency testing, but the method itself is accepted.
Lead time + minimum order?
In-stock dispatch next business day. Count plates come in boxes of 25 or 100 per analyte. No minimum order for stocked lines.
KangarooSci count plates in SA food + beverage QC
SA's food and beverage sector increasingly adopts dry-film count plates over traditional agar for QC testing — faster workflow, simpler technique, less consumable waste, equivalent accuracy. SANAS-accredited labs validate the method per their scope. We stock the KangarooSci range (Aerobic + Coliform + E. coli + Yeast & Mould + Staph. aureus + the ATP hygiene kit) locally with SA business-hours technical support on method adoption + proficiency-testing programmes.